DESCRIPTION
CP-750 is a concentrated liquid alkaline cleaning agent
formulated for the pharmaceutical, biotechnology, cosmetic
and medical device industries. It is our most effective
all-in-one agent to remove a wide range of process and
product residues, including proteins, synthetic organics,
excipients, fine chemicals and is particularly effective
against oils, petrolantums and waxes. This product reduces
the use of solvents and detergent additives. When used
as directed, CP-750 is safe for use on both glass and
stainless steel substrates and on a wide variety of plastics.
The product is not recommended for aluminum, brass, copper
or other soft metals.
The enhanced surfactant system in CP-750 remains effective
across a wide temperature range for improved cleaning
and rinsing in low volume/high energy recirculating spray
systems. It also remains effective even during pH neutralization
prior to sewer discharge, thus reducing redeposition of
removed residues.
CP-750 is low foaming at all temperatures and will not
cavitate recirculation pumps. Extremely free rinsing,
CP-750 provides a clean, residue free surface and provides
excellent hard water tolerance that eliminates mineral
deposits. This cleaning agent is phosphate free. |
DIRECTIONS
CP-750 is designed for use in immersion, pressure spray and
in recirculating spray wash applications and is ideal for recirculating
Clean-In-Place (CIP) systems. Typical operating concentrations
of CP-750 vary from 0.5% to 10% (v/v), depending on temperatures,
soil loads, and cleaning methods used. Proper care and protective
equipment are required for manual cleaningósee the MSD
sheet.
Biodecontamination
Group Technical Service chemists and engineers will help you
establish an improved cleaning procedure for your applications
using CP-750. If required, our testing laboratory can test
your residue and screen various cleaner concentrations, temperatures
and exposure times to determine the optimum cleaning conditions
and also provide cleaning validation assistance.
Concentration
Testing for CP-750- Several options exist for the feed and
concentration control of CP-750, including a standard acid/base
titration, pH and conductivity.
Residue
Testing for CP-750- Standard analytical methods may be used
for determining absence of CP-750 on product contact surfaces.
Acidity titrations, chelant assays, specific ion analysis,
conductivity, pH and Total Organic Carbon (TOC) are all viable
methods of analysis. Let us assist you in your choice of appropriate
methodology.
|