CITRIC ACID
CLEANER/DESCALER
DESCRIPTION
CP-460 is a phosphate-free liquid organic acid cleaner/descaler formulated for the pharmaceutical, cosmetic, and medical device industries. The organic acid effectively removes a wide range of process and research residues, such as inorganic salts and scales, particulate carbon and urine scales. This product is effective in animal cage wash applications, laboratory glassware washing and pharmaceutical/biotech process cleaning.

Low foaming CP-460 will not cavitate recirculation pumps. CP-460 is extremely free rinsing to achieve a clean, residue free surface and has excellent hard water tolerance to eliminate mineral deposits. The enhanced surfactant system improves cleaning and rinsing in low volume/high energy recirculating spray and remains effective across a wide temperature and pH range even during pH neutralization prior to discharge, thus reducing redeposition of process residues. When used as directed, CP-460 is safe for use on both glassware and stainless steel substrates and a wide variety of plastics including polycarbonate.

DIRECTIONS

CP-460 is designed for use in immersion, pressure spray, and recirculating spraywash applications and is ideal for pharmaceutical glassware and parts washing machines and recirculating Clean-In-Place (CIP) systems. Typical operating concentrations of CP-460 run from 0.2% to 5% (v/v), and depend on temperatures, soil loads, and cleaning methods used. Proper care and protective equipment are required for manual cleaning-see the MSD sheet.

Biodecontamination Group Technical Service chemists and engineers will help you establish an improved cleaning procedure for your applications using CP-460. If required, our testing laboratory can test your residue and screen various cleaner concentrations, temperatures and exposure times to determine the optimum cleaning conditions and also provide cleaning validation assistance.

Concentration Testing for CP-460 - Several options exist for the feed and concentration control of CP-460, including a standard acid/base titration, pH and conductivity.

Residue Testing for CP-460 - Standard analytical methods may be used for determining absence of CP-460 on product contact surfaces. Acidity titrations, chelant assays, specific ion analysis, conductivity, pH and Total Organic Carbon (TOC) are all viable methods of analysis. Let us assist you in your choice of appropriate methodology.