CP-400
PHOSPHATE FREE
HYDROXYACATIC ACID
CLEANER |
|
DESCRIPTION
CP-400 is a phosphate-free liquid hydroxyacetic acid cleaner/descaler
formulated for the pharmaceutical, cosmetic, medical device
and food and beverage industries. It effectively removes
a wide range of process and research residues, such as
inorganic salts and scales, particulate carbon and urine
scales. This product is very effective in animal cage
wash applications, glassware washing, and pharmaceutical/biotech
process cleaning and derouging. Low
foaming CP-400 will not cavitate recirculation pumps.
CP-400 is extremely free rinsing to achieve a clean,
residue free surface and has excellent hard water tolerance
to eliminate mineral deposits. The surfactant system
in CP-400 remains effective across a wide temperature
and pH range, even during pH neutralization prior to
discharge, thus reducing redeposition of process reidues.
When used as directed, CP-400 is safe for use on both
glassware and stainless steel substrates and a wide
variety of plastics including polycarbonate.
|
DIRECTIONS
Typical operating concentrations of CP-400 run from 0.2% to
5.0% (v/v), and depend on temperatures, soil loads, and cleaning
methods used. CP-400 is designed for use in immersion, pressure
spray and recirculating spraywash applications and is ideal
for glassware and animal cage washing machines and recirculating
Clean-in-Place (CIP) systems. Higher concentrations are typically
used for periodic derouging and descaling. Proper care and protective
equipment are required for manual cleaning—see the MSD
sheet.
Biodecontamination Group Technical Service Chemists and Engineers
will help you establish an improved cleaning procedure and a
residue testing procedure for your applications using CP-400.
If required, our testing laboratory can test your residue and
screen various cleaner concentrations, temperatures and exposure
times to determine the optimum cleaning conditions and also
provide cleaning validation assistance.
Concentration Testing for CP-400- Several options exist for
the feed and concentration control of CP-400, including a standard
acid/base titration, pH and conductivity.
Residue Testing for CP-400- Standard analytical methods may
be used for determining absence of CP-400 on product contact
surfaces. Surfactant titrations, chelant assays, specific ion
analysis, conductivity, pH and Total Organic Carbon (TOC) are
all viable methods of analysis. Let us assist you in your choice
of appropriate methodology.
|
|
|